northfranklin-k12 2017-05-12


Job Information

Job ID1
ContractorUniversity of Washington
Customernorthfranklin-k12
Report Date2017-05-12 15:01:54
Operator Nameenneking
Circuit IDNoelComm:3115

File Name: C:\inetpub\wwwroot\performance_reports\northfranklin-k12\northfranklin-k12_2017-05-12_fail-abort.html
Comment: was failing, aborted early

Table of Contents

1. Summary


1. Summary

1.1. Alarm

1.1.1. Alarms

1.1.1.1. Global

AlarmH
GlobalFault
Log FullNo Fault


1.1.1.2. Physical

AlarmH
LOSNo Fault
FrequencyNo Fault
LOCNo Fault

Signal AnalysisValue
Pwr (dBm)-1.7

Frequency AnalysisValue
Freq (bps)10312518208.0
Offset (ppm)2


1.1.1.3. WIS

No information is available

1.1.1.4. Ethernet

AlarmH
ErrorFault
LinkNo Fault
FaultNo Fault


1.1.1.5. Higher Layer Protocol

AlarmH
ErrorNo Fault


1.1.1.6. Pattern

No information is available

1.1.1.7. Other

AlarmH
SDTNo Fault


1.1.2. Logger

1.1.2.1. Logger Events

IDDate/TimeData PathEventDurationCountRate
12017-05-12 13:40:40Test 1Test Started
22017-05-12 13:41:14Optical [P1]/Ethernet Framed Layer 2/Traffic Stream [P4]/Stream[4]Out Of SequencePending.
32017-05-12 13:41:14Optical [P1]/Ethernet Framed Layer 2/Traffic Stream [P4]/Stream[4]Frame LossPending.
42017-05-12 13:41:14Optical [P1]/Ethernet Framed Layer 2/Traffic Stream [P2]/Stream[2]Out Of SequencePending.
52017-05-12 13:41:14Optical [P1]/Ethernet Framed Layer 2/Traffic Stream/Stream[1]Out Of SequencePending.
62017-05-12 13:41:14Optical [P1]/Ethernet Framed Layer 2/Traffic Stream [P3]/Stream[3]Out Of SequencePending.
72017-05-12 13:41:19Optical [P1]/Ethernet Framed Layer 2/Traffic Stream/Stream[1]Out Of SequencePending.
82017-05-12 13:41:21Optical [P1]/Ethernet Framed Layer 2/Traffic Stream/Stream[1]Frame LossPending.
92017-05-12 13:42:17Test 1Test Stopped


1.2. Test

1.2.1. Test Status

ItemValue
Start Time: 2017-05-12 13:40:40
Port 1 LinkUp


1.2.2. Test Configuration

ItemValue
Application TypeEtherSAM (Y.1564)
Test NameBV10.EtS
Test Description


1.2.3. Test Preferences

No information is available

1.2.4. Clock Configuration

ItemValue
Clock ModeInternal


1.2.5. Alarm Analysis

AlarmHSeconds
LOCNo Fault0


1.2.6. Timer Configuration

ItemValue
Start Time StatusDisabled
Start Time2015-07-20 12:19:45
Stop Time StatusDisabled
Stop Time2015-07-20 12:19:45
Duration StatusDisabled
Duration15 minutes
On/Off StateDisabled